Part number DB102202 described as Reactor Transformer of Dbp Microwave Inc is now available and in stock. Are you looking for a quick quote for a part number DB102202? Just fill out the short Request for Quote (RFQ) form to get started.The RFQ form has several asterisk-marked (*) fields like Need Parts By and Quantity (ea). Your quote will be determined mainly by your response to these fields, so it’s important that you completely fill out all fields to the best of your abilities. A sales representative will get back to you with your quote in 15 minutes or less. NSN Axis, owned and operated by ASAP Semiconductor, is proud to be a leading online distributor of Dbp Microwave Inc parts and components for the aerospace, aviation, industrial, and military industries. With more than 10 million unique parts searchable by both part number and National Stock Number (NSN), we make it easy for our customers to find all the parts they need.
As an AS9120B, ISO 9001:2015, and FAA AC 0056B accredited member of the Aviation Suppliers Association (ASA), we’ve proudly served clients in the aviation and defense industries around the world. With same-day shipping facilities. The National Stock Number, or NATO Stock Number (NSN), is a 13-digit serial number used by the United States Department of Defense and all members of the North Atlantic Treaty Organization (NATO) to organize items that are procured, stocked, and issued through the federal supply system. To know more about Part number DB102202 under NSN 5950012485938, please call us at our toll-free number, +17147054780, or email us at sales@nsnaxis.com.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-248-5938 Item Description: Reactor Transformer | 5950 | 012485938 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Db102202 | 6 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHY | TURN QUANTITY | 1 4TH COMPONENT SINGLE PRIMARY |
ABHY | TURN QUANTITY | 105 2ND COMPONENT SINGLE WINDING |
ABHY | TURN QUANTITY | 12 3RD COMPONENT 3RD SECONDARY |
ABHY | TURN QUANTITY | 25 3RD COMPONENT 4TH SECONDARY |
ABHY | TURN QUANTITY | 32 3RD COMPONENT SINGLE PRIMARY |
ABHY | TURN QUANTITY | 4 3RD COMPONENT 1ST SECONDARY |
ABHY | TURN QUANTITY | 48 3RD COMPONENT 2ND SECONDARY |
ABHY | TURN QUANTITY | 500 4TH COMPONENT SINGLE SECONDARY |
ABHY | TURN QUANTITY | 7 1ST COMPONENT SINGLE WINDING |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.800 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACYV | INDUCTANCE RATING | 10.00 MICROHENRIES NOMINAL 1ST COMPONENT SINGLE WINDING |
ACYV | INDUCTANCE RATING | 90.00 MICROHENRIES MINIMUM 2ND COMPONENT SINGLE WINDING AND 3.10 MILLIHENRIES MAXIMUM 2ND COMPONENT SINGLE WINDING |
ACZB | FREQUENCY RATING | 20.0 KILOHERTZ NOMINAL 2ND COMPONENT |
ACZB | FREQUENCY RATING | 20.0 KILOHERTZ NOMINAL 3RD COMPONENT |
ACZB | FREQUENCY RATING | 20.0 KILOHERTZ NOMINAL 4TH COMPONENT |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL 1ST COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE 3RD COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE 4TH COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO TERMINAL 3RD COMPONENT |
ADAQ | BODY LENGTH | 3.300 INCHES MAXIMUM |
ADAT | BODY WIDTH | 2.010 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 1.630 INCHES MAXIMUM |
AGAV | END ITEM IDENTIFICATION | C5B ACFT; WSD: AIRCRAFT, GALAXY C-5 |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
BKPL | RATING METHOD | ELECTRICAL 1ST COMPONENT SINGLE WINDING AND WINDING TURNS 1ST COMPONENT SINGLE WINDING |
BKPL | RATING METHOD | ELECTRICAL 2ND COMPONENT SINGLE WINDING AND WINDING TURNS 2ND COMPONENT SINGLE WINDING |
BKPL | RATING METHOD | ELECTRICAL 3RD COMPONENT 1ST SECONDARY AND WINDING TURNS 3RD COMPONENT 1ST SECONDARY |
BKPL | RATING METHOD | ELECTRICAL 3RD COMPONENT 2ND SECONDARY AND WINDING TURNS 3RD COMPONENT 2ND SECONDARY |
BKPL | RATING METHOD | ELECTRICAL 3RD COMPONENT 3RD SECONDARY AND WINDING TURNS 3RD COMPONENT 3RD SECONDARY |
BKPL | RATING METHOD | ELECTRICAL 3RD COMPONENT 4TH SECONDARY AND WINDING TURNS 3RD COMPONENT 4TH SECONDARY |
BKPL | RATING METHOD | ELECTRICAL 3RD COMPONENT SINGLE PRIMARY AND WINDING TURNS 3RD COMPONENT SINGLE PRIMARY |
BKPL | RATING METHOD | WINDING TURNS 4TH COMPONENT SINGLE PRIMARY |
BKPL | RATING METHOD | WINDING TURNS 4TH COMPONENT SINGLE SECONDARY |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY 3RD COMPONENT AND 6 SECONDARY 3RD COMPONENT |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY 4TH COMPONENT AND 1 SECONDARY 4TH COMPONENT |
CQPZ | WINDING CONDUCTOR SIZE | 0.00200 INCHES AMERICAN WIRE GAGE 1ST COMPONENT SINGLE WINDING |
CQPZ | WINDING CONDUCTOR SIZE | 0.00500 INCHES AMERICAN WIRE GAGE 4TH COMPONENT SINGLE SECONDARY |
CQPZ | WINDING CONDUCTOR SIZE | 0.01594 INCHES AMERICAN WIRE GAGE 3RD COMPONENT 1ST SECONDARY |
CQPZ | WINDING CONDUCTOR SIZE | 0.01594 INCHES AMERICAN WIRE GAGE 3RD COMPONENT 2ND SECONDARY |
CQPZ | WINDING CONDUCTOR SIZE | 0.01594 INCHES AMERICAN WIRE GAGE 3RD COMPONENT 3RD SECONDARY |
CQPZ | WINDING CONDUCTOR SIZE | 0.01594 INCHES AMERICAN WIRE GAGE 3RD COMPONENT 4TH SECONDARY |
CQPZ | WINDING CONDUCTOR SIZE | 0.02257 INCHES AMERICAN WIRE GAGE 2ND COMPONENT SINGLE WINDING |
CQPZ | WINDING CONDUCTOR SIZE | 0.02535 INCHES AMERICAN WIRE GAGE 3RD COMPONENT SINGLE PRIMARY |
CQPZ | WINDING CONDUCTOR SIZE | 0.02535 INCHES AMERICAN WIRE GAGE 4TH COMPONENT SINGLE PRIMARY |
CRBZ | WINDING OPERATING CURRENT | 29.0 AMPERES DC MAXIMUM 2ND COMPONENT SINGLE WINDING |
CRBZ | WINDING OPERATING CURRENT | 30.0 AMPERES DC NOMINAL 1ST COMPONENT SINGLE WINDING |
CRGS | DC RESISTANCE RATING IN OHMS | 0.046 3RD COMPONENT SINGLE PRIMARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.120 3RD COMPONENT 3RD SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.132 3RD COMPONENT 1ST SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.240 3RD COMPONENT 4TH SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.760 3RD COMPONENT 2ND SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 14.000 4TH COMPONENT SINGLE SECONDARY |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
CWJS | WINDING OPERATING VOLTAGE | 0.10 AC VOLTS NOMINAL 1ST COMPONENT SINGLE WINDING |
CWJS | WINDING OPERATING VOLTAGE | 15.60 AC VOLTS NOMINAL 3RD COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 2.00 AC VOLTS NOMINAL 2ND COMPONENT SINGLE WINDING |
CWJS | WINDING OPERATING VOLTAGE | 2.50 AC VOLTS NOMINAL 3RD COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 20.00 AC VOLTS NOMINAL 3RD COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 30.00 AC VOLTS NOMINAL 3RD COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 7.48 AC VOLTS NOMINAL 3RD COMPONENT 3RD SECONDARY |
FEAT | SPECIAL FEATURES | WEAPON SYSTEM ESSENTIAL |
TTQY | TERMINAL TYPE AND QUANTITY | 28 TURRET |
accelerometer |
actuator linear worm gear |
boss assembly gearbox duct |
bed bunk |
cover nozzle |
ferrule grooved cla |
gage tiebolt |
hook assy |
intake air cleaner |
kit seal |
You Can Click on "Request For Quote" Button for Your Needs of Any Kind of NSN Parts. 24/7 Quotation Facility is Available.